Features
◇ Simple structure, integrated with vacuum pump, long lifetime.
◇ High vacuum flow, suitable for handling light and porous objects like cellphone screen,perforated plate and fiber sheet.
◇ Easy to install and maintain, cost effective.
How to order | |||||
SLP 40 - M10 Y D - F1 ① ② ③ ④ ⑤ ⑥ | |||||
① Series | ② Dimension | ③ Specification of vacuum pump | ④ Exhaust direction | ⑤ Vacuum breaking function | ⑥ Mounting (flange) |
SLP | 40 - φ40mm 60 - φ60mm (POM material) | M10- Airway φ10mm Breaking M20- Airway φ20mm Vertical exhaust M30- Airway φ30mm Vertical exhaust | Y -Lateral exhaust (Fitting) S -Vertical exhaust (With silencer) T -Vertical exhaust (With pagoda fitting) | Nil - Without breaking function D - With vacuum breaking/ detection function | F1- 55×6mm F3- 63×11mm F4- 95×11mm F5 - 110×13mm |
Selection | ||||||||||
Series | Diameter of suction cup | Specification of vacuum pump | Exhaust direction | Breaking function/Vacuum detectionfunction D | Mounting | |||||
Y T | S | T | F1 | F3 | F4 | F5 | ||||
SLP | 40 | M10 | ● | - | - | ● | ● | ● | - | - |
- | ● | - | - | - | ● | - | - | |||
- | - | ● | - | ● | ● | - | - | |||
60 | M20 | - | ● | ● | - | - | - | ● | - | |
M30 | - | ● | ● | - | - | - | - | ● |
◇Note: "●"- standard, in stock. "—"- unavailable.
Technical parameters | ||||||||||
Model | Working temperature (°C) | Operating pressure range (bar) | Air supply pressure (bar) | Max. vacuum flow (NL/min) | Max. air consumption (NL/min) | Max. vacuum level (-kPa) | ||||
SLP40-M10 | 0~60(Non-freezing) | 1-7 | 5 | 520 | 150 | 13 | ||||
SLP60-M20 | 1,760 | 245 | 5 | |||||||
SLP60-M30 | 2,320 | 375 | 4 |
Vacuum flow (NL/min) at different vacuum levels (-kPa) | |||||||||||
Model | Air supply pressure (bar) | Air consumption (NL/min) | 0 | 1.5 | 2.5 | 3.5 | 4.5 | 5.5 | 6.5 | 7.5 | 13 |
SLP40-M10 | 5 | 150 | 520 | 500 | 460 | 410 | 340 | 290 | 240 | 160 | 90 |
SLP60-M20 | 5 | 245 | 1,760 | 1,620 | 1,380 | 1,180 | 950 | - | - | - | - |
SLP60-M30 | 5 | 375 | 2,320 | 2,070 | 1,870 | 1,580 | - | - | - | - | - |
Evacuation time(S/L) to reach different vacuum levels(-kPa) | ||||||||||||
Model | Air supply pressure (bar) | Air consumption (NL/min) | 0 | 1.5 | 2.5 | 3.5 | 4.5 | 5.5 | 6.5 | 7.5 | 13 | Max. vacuum level (-kPa) |
SLP40-M10 | 5 | 150 | 0.1 | 0.12 | 0.13 | 0.15 | 0.18 | 0.21 | 0.25 | 0.38 | 0.7 | 13 |
SLP60-M20 | 5 | 245 | 0.04 | 0.05 | 0.06 | 0.07 | 0.08 | - | - | - | - | 5 |
SLP60-M30 | 5 | 375 | 0.03 | 0.035 | 0.04 | 0.045 | - | - | - | - | - | 3.5 |